Generac Archives https://www.mjmacinc.com/tag/generac/ Air Conditioning, Heating, Commercial Refrigeration - Hatboro PA (215) 674-4001 Fri, 07 Mar 2014 16:25:49 +0000 en-US hourly 1 https://wordpress.org/?v=6.2.5 Generac QT07068C 70KW/68KW Liquid-Cooled Standby Generator https://www.mjmacinc.com/product/generac-qt07068c-70kw68kw-liquid-cooled-standby-generator/ Fri, 07 Mar 2014 16:25:18 +0000 http://www.mjmacinc.com/?post_type=product&p=1990 Typical Use  Commercial Enclosure Type  Aluminum Cooling Type  Liquid Cooled Phases  1 or 3 Phase Maximum AC Output  70KW Rated AC Current  279 amps @120V/240 (1-ph) (See Spec Sheet for more) Rated Voltage  120V/240V Noise Level  65 dbA @ 7m Fuel Consumption  NG – cu.ft./hr. Exercise 110 1/4 Load 260 1/2 Load 500 3/4 Load […

The post Generac QT07068C 70KW/68KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Typical Use  Commercial Enclosure Type  Aluminum Cooling Type  Liquid Cooled Phases  1 or 3 Phase Maximum AC Output  70KW Rated AC Current  279 amps @120V/240 (1-ph) (See Spec Sheet for more) Rated Voltage  120V/240V Noise Level  65 dbA @ 7m Fuel Consumption  NG – cu.ft./hr. Exercise 110 1/4 Load 260 1/2 Load 500 3/4 Load 696 Full Load 1020 LP – gal/hr Exercise 1.2 1/4 Load 2.85 1/2 Load 5.46 3/4 Load 7.62 Full Load 11.17

The post Generac QT07068C 70KW/68KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Generac QT04854C 48KW/46KW Liquid-Cooled Standby Generator https://www.mjmacinc.com/product/generac-qt04854c-48kw46kw-liquid-cooled-standby-generator/ Fri, 07 Mar 2014 16:20:07 +0000 http://www.mjmacinc.com/?post_type=product&p=1989 Type Synchronous Single Phase Output Alternator Leads  4 wire Three Phase Output Alternator Leads 6 wire (Standby Rating) Load Capacity 48 kW Voltage regulating Type Electronic Sensing Single Phase Regulation +/- 1 percent Engine Make & Model Generac V8 Cylinders 8 Displacement 5.4 Liters Bore 3.55 Stroke 4.17 Compression ratio 9 to 1 Lubrication Oil, geared […

The post Generac QT04854C 48KW/46KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Type
Synchronous
Single Phase Output Alternator Leads 
4 wire
Three Phase Output Alternator Leads
6 wire
(Standby Rating) Load Capacity
48 kW
Voltage regulating
Type
Electronic
Sensing
Single Phase
Regulation
+/- 1 percent
Engine
Make & Model
Generac V8
Cylinders
8
Displacement
5.4 Liters
Bore
3.55
Stroke
4.17
Compression ratio
9 to 1
Lubrication
Oil, geared pump with filter
6.5 quart capacity
Cooling
Belt driven water pump, 22 inch fan
Fuel type
Propane, Natural Gas
Electrical
Battery charging alternator
12 Volts 30 Amps
Static battery charging
2 Amps
Battery recommendation
525CCA, Group 24F
Voltage
12 Volts

 

Operation Specifications

Output Volatge kW LP Amps CB Size
120 / 240 Volts, 1 phase, 1 pf
120 / 208 Volts, 3 phase, 0.8 pf
120 / 240 Volts, 3 phase, 0.8 pf
277 / 480 Volts, 3 phase, 0.8 pf

48

200
166
144
72

200
175
150
80

Fuel Consumption
 
Exercise cycle
25 percent rated load
50 percent rated load
75 percent rated load
100 percent rated load*
For Btu, multiply ft3 / hr by 2520 (for LP)
or ft3 / hr by 1000 (for NG)
Natural Gas
(ft3 / hr.)
95
204
392
547
756
Propane
(gal. / hour)    ft3 / hr
2.0         38
2.16       82
4.14      157
5.8       220
7.96      302
Engine Cooling
Air-flow (inlet air incl. alternator & combustion air)
Coolant capacity
Heat rejection – coolant
Maximu operating temp. for radiator
Maximum ambient temp.

4350 ft3 / min.
3 US gallons
186,000 BTU / hour
60 deg. C (150 deg F)
50 deg. C (140 deg F)

Combustion air Flow @ rated power 60Hz – 163 CFM
Sound Emission Exercising @ 7 m – 63 dBA
Normal operation @ 7 m – 68 dBA
Exhaust
Exhaust flow @ rated output 60Hz
Exhaust temp. @ muffler outlet
414 CFM
1025 deg. F
Ambient conditions power adjustment
Temperature Deration
3 percent for every 10 deg. above 25 deg. C
1.65 percent for every 10 deg. above 77 deg. F
Altitude Deration
1 percent for every 100 meters above 183 meters
3 percent for every 1000 feet above 600 feet

The post Generac QT04854C 48KW/46KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Generac QT04854 QuietSource Series https://www.mjmacinc.com/product/generac-qt04854-quietsource-series/ Fri, 07 Mar 2014 16:16:39 +0000 http://www.mjmacinc.com/?post_type=product&p=1988 Auto Shutdown:  Yes Battery Included:  No Battery Type:  Group 24F, 525CCA Carb Compliant:  No Combustion Air Requirement:  235 CFM Compression Ratio:  9.3 Coolant Capacity:  3.0 Gallons Cooling System:  Liquid-Cooled Cylinder Arrangement:  V-8 Depth:  45-in Enclosure Color:  Grey Enclosure Type:  Aluminum Engine Cool-Down:  1 Minute Engine Cooling Air Flow:  2,460 cubic ft/min. Engine Warm-Up:  5 Seconds […

The post Generac QT04854 QuietSource Series appeared first on M. J. Mac Inc..

]]>
Auto Shutdown:  Yes Battery Included:  No Battery Type:  Group 24F, 525CCA Carb Compliant:  No Combustion Air Requirement:  235 CFM Compression Ratio:  9.3 Coolant Capacity:  3.0 Gallons Cooling System:  Liquid-Cooled Cylinder Arrangement:  V-8 Depth:  45-in Enclosure Color:  Grey Enclosure Type:  Aluminum Engine Cool-Down:  1 Minute Engine Cooling Air Flow:  2,460 cubic ft/min. Engine Warm-Up:  5 Seconds Engine Size:  5.4L Fuel Type:  Natural Gas Governor System:  Electronic Horsepower:  75 HP Ignition System:  Solid-state Length:  77-in Liquid Propane Fuel Consumption at Full Load:  8.28 Gallons Per Hour Model:  QuietSource Natural Gas Fuel Consumption at Full Load:  784 cubic ft/hour Noise Level:  68 dB at 23 ft. Operating RPM:  1,800 Phase:  3 Power Factor:  1 Quiet Test Mode:  Yes Rated AC Frequency:  60Hz Rated Watts:  48 kW Rotor Insulation:  Class H Starter:  12 Vdc Total Harmonic Distortion:  Less than 5% Transfer Switch Required:  RTS Transfer Switch:  Sold Separately Type:  Commercial Standby Valve Seats:  Precision Ground and Hardened Voltage:  120/240 Weight:  1,702 lbs. Width:  34-in

The post Generac QT04854 QuietSource Series appeared first on M. J. Mac Inc..

]]>
Generac QT03624 QT 03624 Quietsource Auto Standby Generator 36kW https://www.mjmacinc.com/product/generac-qt03624-qt-03624-quietsource-auto-standby-generator-36kw/ Fri, 07 Mar 2014 16:14:15 +0000 http://www.mjmacinc.com/?post_type=product&p=1986 Type Synchronous Three Phase Output Alternator Leads  4 wire (Standby Rating) Load Capacity 36 kW Voltage regulating Type Electronic Sensing Single Phase Regulation +/- 1 percent Engine Make & Model Generac Inline 4 Cylinder Cylinders 4 Displacement 2.4 Liters Bore 3.41 Stroke 3.94 Compression ratio 9.5 to 1 Lubrication Oil, geared pump with filter 4 quart capacity Cooling […

The post Generac QT03624 QT 03624 Quietsource Auto Standby Generator 36kW appeared first on M. J. Mac Inc..

]]>
Type
Synchronous
Three Phase Output Alternator Leads 
4 wire
(Standby Rating) Load Capacity
36 kW
Voltage regulating
Type
Electronic
Sensing
Single Phase
Regulation
+/- 1 percent
Engine
Make & Model
Generac Inline 4 Cylinder
Cylinders
4
Displacement
2.4 Liters
Bore
3.41
Stroke
3.94
Compression ratio
9.5 to 1
Lubrication
Oil, geared pump with filter
4 quart capacity
Cooling
Belt driven water pump, 22 inch fan
Fuel type
Propane, Natural Gas
Electrical
Battery charging alternator
12 Volts 30 Amps
Static battery charging
2 Amps
Battery recommendation
525CCA, Group 26
Voltage
12 Volts

 

Operation Specifications

Output Volatge kW LP Amps kW Nat. Gas

Amps

CB Size (both)
120 / 240 Volts, 1 phase, 1 pf
120 / 208 Volts, 3 phase, 0.8 pf
120 / 240 Volts, 3 phase, 0.8 pf
277 / 480 Volts, 3 phase, 0.8 pf

36

150
125
108
54

35

146
121
105
52

175
150
125
60

Fuel Consumption
 
Exercise cycle
25 percent rated load
50 percent rated load
75 percent rated load
100 percent rated load*
For Btu, multiply ft3 / hr by 2520 (for LP)
or ft3 / hr by 1000 (for NG)
Natural Gas
(ft3 / hr.)
48
156
282
392
503
Propane
(gal. / hour)    ft3 / hr
0.5             19
1.7 
           62
3.1            112
4.3            156
5.5            200
Engine Cooling
Air-flow (inlet air incl. alternator & combustion air)
Coolant capacity
Heat rejection – coolant
Maximu operating temp. for radiator
Maximum ambient temp.

2200 ft3 / min.
2.5 US gallons
145,000 BTU / hour
60 deg. C (150 deg F)
50 deg. C (140 deg F)

Combustion air Flow @ rated power 60Hz – 106 CFM
Sound Emission Exercising @ 7 m – 58 dBA
Normal operation @ 7 m – 64 dBA
Exhaust
Exhaust flow @ rated output 60Hz
Exhaust temp. @ muffler outlet
300 CFM
1075 deg. F
Ambient conditions power adjustment
Temperature Deration
3 percent for every 10 deg. above 25 deg. C
1.65 percent for every 10 deg. above 77 deg. F
Altitude Deration
1 percent for every 100 meters above 915 meters
3 percent for every 1000 feet above 3000 feet

The post Generac QT03624 QT 03624 Quietsource Auto Standby Generator 36kW appeared first on M. J. Mac Inc..

]]>
Generac QT02724 QT 02724 Quietsource Auto Standby Generator 27kW https://www.mjmacinc.com/product/generac-qt02724-qt-02724-quietsource-auto-standby-generator-27kw/ Fri, 07 Mar 2014 16:11:58 +0000 http://www.mjmacinc.com/?post_type=product&p=1985 Type Synchronous Three Phase Output Alternator Leads  4 wire (Standby Rating) Load Capacity 27 kW Voltage regulating Type Electronic Sensing Single Phase Regulation +/- 1 percent Engine Make & Model Generac Inline 4 Cylinder Cylinders 4 Displacement 2.4 Liters Bore 3.41 Stroke 3.94 Compression ratio 9.5 to 1 Lubrication Oil, geared pump with filter 4 quart capacity Cooling […

The post Generac QT02724 QT 02724 Quietsource Auto Standby Generator 27kW appeared first on M. J. Mac Inc..

]]>
Type
Synchronous
Three Phase Output Alternator Leads 
4 wire
(Standby Rating) Load Capacity
27 kW
Voltage regulating
Type
Electronic
Sensing
Single Phase
Regulation
+/- 1 percent
Engine
Make & Model
Generac Inline 4 Cylinder
Cylinders
4
Displacement
2.4 Liters
Bore
3.41
Stroke
3.94
Compression ratio
9.5 to 1
Lubrication
Oil, geared pump with filter
4 quart capacity
Cooling
Belt driven water pump, 18.1 inch fan
Fuel type
Propane, Natural Gas
Electrical
Battery charging alternator
12 Volts 30 Amps
Static battery charging
2 Amps
Battery recommendation
525CCA, Group 26
Voltage
12 Volts

 

Operation Specifications

Output Volatge kW LP Amps kW Nat. Gas

Amps

CB Size (both)
120 / 240 Volts, 1 phase, 1 pf
120 / 208 Volts, 3 phase, 0.8 pf
120 / 240 Volts, 3 phase, 0.8 pf

27

112
94
81

25

104
87
75

125
100
90

Fuel Consumption
 
Exercise cycle
25 percent rated load
50 percent rated load
75 percent rated load
100 percent rated load*
For Btu, multiply ft3 / hr by 2520 (for LP)
or ft3 / hr by 1000 (for NG)
Natural Gas
(ft3 / hr.)
42
108
197
287
359
Propane
(gal. / hour)    ft3 / hr
0.44             16
1.2             44
2.1             78
3.1            114
3.9            143
Engine Cooling
Air-flow (inlet air incl. alternator & combustion air)
Coolant capacity
Heat rejection – coolant
Maximu operating temp. for radiator
Maximum ambient temp.

2400 ft3 / min.
3 US gallons
105,000 BTU / hour
60 deg. C (150 deg F)
50 deg. C (140 deg F)

Combustion air Flow @ rated power 60Hz – 68 CFM
Sound Emission Exercising @ 7 m – 61 dBA
Normal operation @ 7 m – 70 dBA
Exhaust
Exhaust flow @ rated output 60Hz
Exhaust temp. @ muffler outlet
180 CFM
900 deg. F
Ambient conditions power adjustment
Temperature Deration
3 percent for every 10 deg. above 25 deg. C
1.65 percent for every 10 deg. above 77 deg. F
Altitude Deration
1 percent for every 100 meters above 183 meters
3 percent for every 1000 feet above 600 feet

The post Generac QT02724 QT 02724 Quietsource Auto Standby Generator 27kW appeared first on M. J. Mac Inc..

]]>
Generac QT02224 Generac Generator 22kW https://www.mjmacinc.com/product/generac-qt02224-generac-generator-22kw/ Fri, 07 Mar 2014 16:07:55 +0000 http://www.mjmacinc.com/?post_type=product&p=1984 Liquid Propane Amperage (amps) 92 Natural Gas Amperage (amps) 92 Assembled Length (in.) 63 Assembled Height (in.) 33.5 Assembled Width (in.) 29 Assembled Weight (lbs) 843 Color Family Grays CSA Listed Yes ETL Listed No Commercial / Residential Commercial Engine Displacement (liter) 2.4 Energy Star Compliant No Engine brand Generac Engine Make N/A Frequency (hertz) […

The post Generac QT02224 Generac Generator 22kW appeared first on M. J. Mac Inc..

]]>
Liquid Propane Amperage (amps) 92 Natural Gas Amperage (amps) 92 Assembled Length (in.) 63 Assembled Height (in.) 33.5 Assembled Width (in.) 29 Assembled Weight (lbs) 843 Color Family Grays CSA Listed Yes ETL Listed No Commercial / Residential Commercial Engine Displacement (liter) 2.4 Energy Star Compliant No Engine brand Generac Engine Make N/A Frequency (hertz) 60 Engine Manufacturer Generac Hour Meter Yes Low oil shutdown Yes Manufacturer Warranty 2 Year Limited Response time (sec.) 30 Rated Wattage Liquid Propane (watts) 22,000 Rated Wattage Natural Gas (watts) 22,000

The post Generac QT02224 Generac Generator 22kW appeared first on M. J. Mac Inc..

]]>
Generac QT06024 Guardian Auto Standby Generator 60 kW https://www.mjmacinc.com/product/generac-qt06024-guardian-auto-standby-generator-60-kw/ Fri, 07 Mar 2014 16:05:03 +0000 http://www.mjmacinc.com/?post_type=product&p=1983 Type Synchronous Three Phase Output Alternator Leads  4 wire (Standby Rating) Load Capacity 60 kW Voltage regulating Type Electronic Sensing Single Phase Regulation +/- 1 percent Engine Make & Model Generac Inline 4 Cylinder Cylinders 4 Displacement 2.4 Liters Bore 3.41 Stroke 3.94 Compression ratio 8.5 to 1 Lubrication Oil, geared pump with filter 4 quart capacity Cooling […

The post Generac QT06024 Guardian Auto Standby Generator 60 kW appeared first on M. J. Mac Inc..

]]>
Type
Synchronous
Three Phase Output Alternator Leads 
4 wire
(Standby Rating) Load Capacity
60 kW
Voltage regulating
Type
Electronic
Sensing
Single Phase
Regulation
+/- 1 percent
Engine
Make & Model
Generac Inline 4 Cylinder
Cylinders
4
Displacement
2.4 Liters
Bore
3.41
Stroke
3.94
Compression ratio
8.5 to 1
Lubrication
Oil, geared pump with filter
4 quart capacity
Cooling
Belt driven water pump, 22 inch fan
Fuel type
Propane, Natural Gas
Electrical
Battery charging alternator
12 Volts 30 Amps
Static battery charging
2 Amps
Battery recommendation
525CCA, Group 26
Voltage
12 Volts

 

Operation Specifications

Output Volatge kW Amps

CB Size

120 / 240 Volts, 1 phase, 1 pf
120 / 208 Volts, 3 phase, 0.8 pf
120 / 240 Volts, 3 phase, 0.8 pf
277 / 480 Volts, 3 phase, 0.8 pf

60

250
208
180
90

300
250
200
100

Fuel Consumption
 
Exercise cycle
25 percent rated load
50 percent rated load
75 percent rated load
100 percent rated load*
For Btu, multiply ft3 / hr by 2520 (for LP)
or ft3 / hr by 1000 (for NG)
Natural Gas
(ft3 / hr.)
123
267
483
672
862
Propane
(gal. / hour)    ft3 / hr
1.34           49.3
2.7           101
5.0           183
7.0            255
9.0            327
Engine Cooling
Air-flow (inlet air incl. alternator & combustion air)
Coolant capacity
Heat rejection – coolant
Maximu operating temp. for radiator
Maximum ambient temp.

3280 ft3 / min.
2.5 US gallons
270,000 BTU / hour
60 deg. C (150 deg F)
50 deg. C (140 deg F)

Combustion air Flow @ rated power 60Hz – 180 CFM
Sound Emission Exercising @ 7 m – 65 dBA
Normal operation @ 7 m – 72 dBA
Exhaust
Exhaust flow @ rated output 60Hz
Exhaust temp. @ muffler outlet
494 CFM
1050 deg. F
Ambient conditions power adjustment
Temperature Deration
3 percent for every 10 deg. above 25 deg. C
1.65 percent for every 10 deg. above 77 deg. F
Altitude Deration
1 percent for every 100 meters above 915 meters
3 percent for every 1000 feet above 3000 feet

The post Generac QT06024 Guardian Auto Standby Generator 60 kW appeared first on M. J. Mac Inc..

]]>
Generac QT03015 30KW/27KW Liquid-Cooled Standby Generator https://www.mjmacinc.com/product/generac-qt03015-30kw27kw-liquid-cooled-standby-generator/ Fri, 07 Mar 2014 15:57:44 +0000 http://www.mjmacinc.com/?post_type=product&p=1982 Type Synchronous Three Phase Output Alternator Leads Single Phase Output Alternator Leads 6 wire 4 wire (Standby Rating) Load Capacity 30 kW Voltage regulating Type Electronic Sensing Single Phase Regulation +/- 1 percent Engine Make & Model Generac Inline 4 Cylinder Cylinders 4 Displacement 1.5 Liters Bore 77.4 mm Stroke 79.52 mm Compression ratio 11 to 1 Lubrication Oil, geared […

The post Generac QT03015 30KW/27KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Type
Synchronous
Three Phase Output Alternator Leads
Single Phase Output Alternator Leads
6 wire
4 wire
(Standby Rating) Load Capacity
30 kW
Voltage regulating
Type
Electronic
Sensing
Single Phase
Regulation
+/- 1 percent
Engine
Make & Model
Generac Inline 4 Cylinder
Cylinders
4
Displacement
1.5 Liters
Bore
77.4 mm
Stroke
79.52 mm
Compression ratio
11 to 1
Lubrication
Oil, geared pump with filter
4 quart capacity
Cooling
Belt driven water pump, 17.7 inch fan
Fuel type
Propane, Natural Gas
Electrical
Battery charging alternator
12 Volts 30 Amps
Static battery charging
2 Amps
Battery recommendation
525CCA, Group 26
Voltage
12 Volts

 

Operation Specifications

Output Volatge kW Amps

CB Size

120 / 240 Volts, 1 phase, 1 pf
120 / 208 Volts, 3 phase, 0.8 pf
120 / 240 Volts, 3 phase, 0.8 pf

30

125
104
90

150
125
100

Fuel Consumption
 
Exercise cycle
25 percent rated load
50 percent rated load
75 percent rated load
100 percent rated load*
For Btu, multiply ft3 / hr by 2520 (for LP)
or ft3 / hr by 1000 (for NG)
Natural Gas
(ft3 / hr.)
60
240
320
400
492
Propane
(gal. / hour)    ft3 / hr
0.7            24
2.6            96
3.5           128
4.4           160
5.4           197
Engine Cooling
Air-flow (inlet air incl. alternator & combustion air)
Coolant capacity
Heat rejection – coolant
Maximu operating temp. for radiator
Maximum ambient temp.

1800 ft3 / min.
2 US gallons
135,000 BTU / hour
60 deg. C (150 deg F)
50 deg. C (140 deg F)

Combustion air Flow @ rated power 60Hz – 72 CFM
Sound Emission Exercising @ 7 m – 59 dBA
Normal operation @ 7 m – 73 dBA
Exhaust
Exhaust flow @ rated output 60Hz
Exhaust temp. @ muffler outlet
237 CFM
1130 deg. F
Ambient conditions power adjustment
Temperature Deration
3 percent for every 10 deg. above 25 deg. C
1.65 percent for every 10 deg. above 77 deg. F
Altitude Deration
1 percent for every 100 meters above 183 meters
3 percent for every 1000 feet above 600 feet

The post Generac QT03015 30KW/27KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Generac QT02515 25KW/24KW Liquid-Cooled Standby Generator https://www.mjmacinc.com/product/generac-qt02515-25kw24kw-liquid-cooled-standby-generator/ Fri, 07 Mar 2014 15:54:55 +0000 http://www.mjmacinc.com/?post_type=product&p=1979 Type Synchronous Three Phase Output Alternator Leads Single Phase Output Alternator Leads 6 wire 4 wire (Standby Rating) Load Capacity 25 kW Voltage regulating Type Electronic Sensing Single Phase Regulation +/- 1 percent Engine Make & Model Generac Inline 4 Cylinder Cylinders 4 Displacement 1.5 Liters Bore 77.4 mm Stroke 79.52 mm Compression ratio 11 to 1 Lubrication Oil, geared […

The post Generac QT02515 25KW/24KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Type
Synchronous
Three Phase Output Alternator Leads
Single Phase Output Alternator Leads
6 wire
4 wire
(Standby Rating) Load Capacity
25 kW
Voltage regulating
Type
Electronic
Sensing
Single Phase
Regulation
+/- 1 percent
Engine
Make & Model
Generac Inline 4 Cylinder
Cylinders
4
Displacement
1.5 Liters
Bore
77.4 mm
Stroke
79.52 mm
Compression ratio
11 to 1
Lubrication
Oil, geared pump with filter
4 quart capacity
Cooling
Belt driven water pump, 17.7 inch fan
Fuel type
Propane, Natural Gas
Electrical
Battery charging alternator
12 Volts 30 Amps
Static battery charging
2 Amps
Battery recommendation
525CCA, Group 26
Voltage
12 Volts

 

Operation Specifications

Output Volatge kW Amps

CB Size

120 / 240 Volts, 1 phase, 1 pf
120 / 208 Volts, 3 phase, 0.8 pf
120 / 240 Volts, 3 phase, 0.8 pf

25

104
87
75

125
100
90

Fuel Consumption
 
Exercise cycle
25 percent rated load
50 percent rated load
75 percent rated load
100 percent rated load*
For Btu, multiply ft3 / hr by 2520 (for LP)
or ft3 / hr by 1000 (for NG)
Natural Gas
(ft3 / hr.)
60
220
297
362
430
Propane
(gal. / hour)    ft3 / hr
0.7            24
2.9            88
3.3           119
4             145
4.7           172
Engine Cooling
Air-flow (inlet air incl. alternator & combustion air)
Coolant capacity
Heat rejection – coolant
Maximu operating temp. for radiator
Maximum ambient temp.

1800 ft3 / min.
2 US gallons
112,000 BTU / hour
60 deg. C (150 deg F)
50 deg. C (140 deg F)

Combustion air Flow @ rated power 60Hz – 62 CFM
Sound Emission Exercising @ 7 m – 59 dBA
Normal operation @ 7 m – 72 dBA
Exhaust
Exhaust flow @ rated output 60Hz
Exhaust temp. @ muffler outlet
203 CFM
1100 deg. F
Ambient conditions power adjustment
Temperature Deration
3 percent for every 10 deg. above 25 deg. C
1.65 percent for every 10 deg. above 77 deg. F
Altitude Deration
1 percent for every 100 meters above 183 meters
3 percent for every 1000 feet above 600 feet

The post Generac QT02515 25KW/24KW Liquid-Cooled Standby Generator appeared first on M. J. Mac Inc..

]]>
Generac EcoGen Series 5818- 6kW Standby Generator for Off Grid Applications model 5818 https://www.mjmacinc.com/product/generac-ecogen-series-5818-6kw-standby-generator-for-off-grid-applications-model-5818/ Fri, 07 Mar 2014 15:46:28 +0000 http://www.mjmacinc.com/?post_type=product&p=1977 Voltage 120 Single-Phase Frequency: 60 Hertz Cooling System Air Cooled Fuel Type LP LP Power Capacity 6,000 Watts LP Consumption (50% Load) .82 gallons/hr (BTU: 74,415 BTU/HR) LP Consumption (100% Load) 1.47 gallons/hr (BTU: 133,403 BTU/HR) Rated Amps: 50 Amps @ 120 Volts (Single Phase) Decibel Rating @ 7m: 52 db(A) Enclosure Steel Mounting Pad Composite (Included) Transfer Switch: Not […

The post Generac EcoGen Series 5818- 6kW Standby Generator for Off Grid Applications model 5818 appeared first on M. J. Mac Inc..

]]>
Voltage 120 Single-Phase Frequency: 60 Hertz Cooling System Air Cooled Fuel Type LP LP Power Capacity 6,000 Watts LP Consumption (50% Load) .82 gallons/hr (BTU: 74,415 BTU/HR) LP Consumption (100% Load) 1.47 gallons/hr (BTU: 133,403 BTU/HR) Rated Amps: 50 Amps @ 120 Volts (Single Phase) Decibel Rating @ 7m: 52 db(A) Enclosure Steel Mounting Pad Composite (Included) Transfer Switch: Not Applicable Battery: Not Included (525 CCA – Battery Group 26R)

The post Generac EcoGen Series 5818- 6kW Standby Generator for Off Grid Applications model 5818 appeared first on M. J. Mac Inc..

]]>